Medical Applications
MACtac Medical products and systems are found in various applications, including single-use electrodes, surgical drapes, wound dressings and transdermal drug delivery systems. All products are manufactured in ISO or current Good Manufacturing Practices (cGMP) compliant facilities to ensure product quality and patient comfort.
Main applications

Adhesive electrodes/pads for sustained skin contacts

Surgical drapes

Medical device assembly where skin contact is possible. (aggressive adhesives suitable with polyethylene)

Manufacturing of bandages, wound care and transdermal drug delivery system
See the MACtac Medical Product Offer
| Reference | Short description | Adhesive | Liner | Thickness | Adhesive thickness | Technical Data sheet |
| TM 9616 | Double-sided foam tape coated on two sides with acrylic based, hypoallergenic pressure sensitive adhesive.designed for assembling medical devices where skin contact is possible. It exhibits good adhesion to polyethylene | SBMA | densified, semi-bleached kraft release liner | 1.6 mm | 63.5µ |  |
| TM 9716 | Single-sided tape made of a crosslinked polyethylene foam coated on one side with acrylic based, hypoallergenic pressure sensitive adhesive. Low tack pediatric tape used for EKG pads, Transdermal delivery | SBMA | polycoated white kraft release liner | 1.6 mm | 35.6µ |  |
| TM 9942 NK | crosslinked polyethylene foam coated on one side with 594 acrylic based, hypoallergenic pressure sensitive adhesive. The adhesive is protected by a 107 gr brown polycoated kraft release liner. | SBMA | polycoated white kraft release liner | 0.8 mm | 63.5 µ |  |
| TM 9946 | Single-sided foam tape with acrylic based, hypoallergenic pressure sensitive adhesive. formulated for sustained contact with the human skin. Designed as a general purpose tape used for EKG pads, grounding pads, IV holders. | SBMA | polycoated white kraft release liner | 1.6 mm | 63.5µ |  |
| TM 9947 | Cross linked polyethylene foam coated on one side with acrylic based, hypoallergenic pressure sensitive adhesive. The adhesive is protected by a 80 gr white calendered release liner | SBA | white calendered release liner. | 1 mm | 50 µ |  |
| TM 9710 | Double-sided film with acrylic based, hypoallergenic pressure sensitive adhesive. designed for assembling medical devices where skin contact is possible. The adhesive is very aggressive and bonds well to polyethylene | SBA | densified, semi bleached kraft release liner. | 12.7µ | 35.6µ |  |
| TM 9478 | Single-sided non woven tape coated with acrylic based, hypoallergenic pressure sensitive adhesive. Designed for use as a breathable medical tape : TENS and stress electrodes plus protective pads and covers | SBMA | densified, semi-bleached kraft release liner | 68.5 gr/m² | 355-455 µ |  |
| TM 9479 | Single-sided non woven tape coated on one side with acrylic based, hypoallergenic pressure sensitive adhesive. Designed for use as a breathable medical tape : TENS and stress electrodes plus protective pads and covers | SBMA | densified, semi-bleached kraft release liner | 68.5 gr/m² | 355-455 µ |  |
| TM 9976-60 | Cross linked 1.6 mm polyethylene foam coated on one side with an acrylic based, hypoallergenic pressure sensitive adhesive. The adhesive is protected by a 80 gr semi-bleached SCK paper release liner. | SBMA | 80 gr semi-bleached SCK paper release liner | 1.6 mm | 1643 µ |  |
| TM 9979 | Cross linked polyethylene foam coated on one side with 597acrylic based, hypoallergenic pressure sensitive adhesive. The adhesive is protected by a 80 gr white calendered release liner | SBMA | 80 gr white calendered release liner. | 1.5 mm | 1550 µ |  |